Airline Respirator Standards & Specs
Compressed Air Specifications
Trace Analytics, LLC specializes in the analysis of thousands of compressed breathing air samples each year. Many of our customers have established their own criteria by monitoring the performance of the system over a given time period, reviewing literature/specifications, evaluating equipment parameters, and determining company objectives.
Our scientifically designed compressed air testing kits make collection a simple task. Keep the small, portable kit, and return the lightweight sample via the shipping method of your choice.
The following are some commonly used Airline Respirator Compressed Breathing Air Specifications. If the specification you need is not listed below, please Contact Us. We have many more air & gas specifications in our database. If you need a custom specification, Contact Us with your requirements.
AIRLINE RESPIRATORS - SELECTED AIR QUALITY SPECIFICATIONS | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
AIR QUALITY SPECIFICATION | THC | CO | CH4 | CO2 | H2O | DP, °F | O2 | N2 | OIL | ODOR | OTHER | |
CGA G-7-2011 Grade D (1) | N/A | 10 | N/A | 1000 | N/A | N/A | 19.5-23.5 | N/A | 5 | None/Slight | N/A | |
CGA G-7-2011 Grade D (2) | N/A | 10 | N/A | 1000 | N/A | N/A | 19.5-23.5 | N/A | 5 | None/Slight | N/A | |
CGA G-7.1-2011 Grades D & E (2) | 25 | 10 | N/A | 1000 | N/A | N/A | 20-22 | N/A | 5 | None/Slight | N/A | |
CSA Z180.1-2013 (<15 psig)(N) | N/A | 5 | 10 | 600 | N/A | N/A | 20-22 | N/A | 1 | None/Slight | Halogenated Hydrocarbons, ppmv | |
5 | ||||||||||||
CSA Z180.1-2013 (15-2216 psig)(L) | N/A | 5 | 10 | 600 | N/A | N/A | 20-22 | N/A | 1 | None/Slight | Halogenated Hydrocarbons, ppmv | Pressure Dewpoint, °C |
5 | Subtract 5°C from Lowest Temp; Use -5°C as Default | |||||||||||
OSHA 1910.134 Respiratory Protection-2004 Compressor (O) | N/A | 10 | N/A | 1000 | (O) | (O) | 19.5-23.5 | N/A | 5 | None/Slight | N/A | |
THC = Total Gaseous Hydrocarbons, ppmv CO2 = Carbon Dioxide, ppmv O2 = Oxygen, volume % HS = Halogenated Solvents, ppmv CO = Carbon Monoxide, ppmv H2O = Water, ppmv N2 = Nitrogen, volume % Odor = Odor as supplied by customer CH4 = Methane, ppmv DP = Dew Point, °F at 0 psig Oil = Oil Mist & Particulate, mg/m3 |
||||||||||||
Air & Gas Specifications referenced above may be viewed and/or purchased from: CGA - Compressed Gas Association • CSA - Canadian Standards Association • OSHA - Occupational Health & Safety Administration |
Testing Made SimpleAccurateEasy
Trace Analytics’ laboratory is accredited by the American Association for Laboratory Accreditation. We use state-of-the-art lab equipment that allows us to analyze hundreds of compressed air and environmental samples daily. The result is consistency, accuracy, precision, and rapid turnaround. Trace is an A2LA accredited laboratory complying with ISO 17025, certificate #0322-01.